Abstract

Volume.127 Number.4

Original article : Clinical science

Comparison of Postoperative Visual Acuity in Eyes with Seven Types of Multifocal Intraocular Lenses
Nobuyo Ando, Hiroshi Ando, Ryo Eguchi, Nobuko Ishikawa, Toshie Tonozuka, Aki Kondo
Ando Eye Clinic

Purpose: To compare visual acuity (VA) in eyes (n=1,564) after implantation of seven types of multifocal intraocular lenses (IOL) at a single site from February, 2012 to March, 2020.
Subject and method: Uncorrected and corrected VA were com pared at 5 m, 1 m, 50 cm, and 30 cm at postoperative week one and month 1-3 with extended depth of focus type TECNIS Symfony OptiBlue and its toric (Symfony), n=716; low-add-power segmented type Lentis Comfort (Lentis Comfort), n=91; trifocal Acrisof IQ PanOptix single piece and its toric (PanOptix), n=179; bifocal LENTIS Mplus MF, X, and its toric (Lentis Mplus), n=203; TECNIS Multifocal ZMB00 (ZMB), n=256; ZLB00, n=80; and ZKB00 (ZKB), n=39.
Results: At postoperative month 1-3, the mean subjective spherical equivalent was -0.24 D to+0.05 D and the mean cylindrical power was -0.35 D to -0.17 D, showing significant differences between some groups (p< 0.0024). For 5-m uncorrected VA, Symfony〔-0.02±0.13 logarithmic minimum angle of resolution (logMAR), mean±standard deviation〕 was significantly better than Lentis Comfort (0.05±0.17 logMAR) (p< 0.001) at postoperative week one; but no significant differences were observed across groups at postoperative month 1-3. For 5-m corrected VA, Symfony (-0.09±0.07 logMAR) was significantly better than PanOptix and Lentis Mplus at postoperative week one (p< 0.001). For 1-m uncorrected and corrected VA, Symfony and Lentis Comfort were significantly better than Lentis Mplus and ZMB at postoperative week one and month 1-3 (p< 0.001). For 50-cm uncorrected VA, Symfony, Lentis Comfort, and PanOptix were significantly better than bifocal IOL (except ZKB) at postoperative week one (p< 0.001). For 30-cm uncorrected and corrected VA, PanOptix and bifocal IOL were significantly better than Symfony at almost all time points (p< 0.001). At postoperative month 1-3, postoperative refraction values in all groups became hypermetropic (+0.01-+0.20 D) relative to the target refraction value.
Conclusion: VA was good with Symfony and Lentis Comfort at 5 m, 1 m, and 50 cm; PanOptix at all 4 distances; and 4 types of bifocal IOL at 5 m and 30 cm.
Nippon Ganka Gakkai Zasshi (J Jpn Ophthalmol Soc) 127: 471-483,2023.

Key words
Postoperative visual acuity of multifocal intraocular lens (IOL), Extended depth of focus IOL, Low-add-power segmented IOL, Trifocal IOL, Bifocal IOL
Reprint requests to
Nobuyo Ando, M. D. Ando Eye Clinic. 965-1 Matsudasoryo, Matsuda-machi, Ashigarakami-gun, Kanagawa 258-0003, Japan